BOXLINE MARK FIRE-PROOF E90 ENCLOSURES - WITH PRE-MARKED ENTRIES
back to BOXES FOR SPECIAL INSTALLATIONS
EASY OPENING![marke90entradaNew2](data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%2090%2090%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3C%2Fsvg%3E)
![null](https://jsl-online.com/wp-content/uploads/2020/03/marke90caixas.png)
![e90 fire proof boxes enclosures JSL markej100](https://jsl-online.com/wp-content/uploads/2020/03/markej100.png)
Made of RAL 2003 Orange Copolymer thermoplastic Blend resistant to Fire and incandescent wire at 960ºC according to Standards: IEC EN 60695-2-12 and IEC EN 60695-11-10, considered V0 according to Standard UL94
E90 FIRE RESISTANT BOXES ARE APPROPRIATE FOR:
![AmbientesFire2 AmbientesFire2](https://jsl-online.com/wp-content/uploads/2020/03/AmbientesFire2.png)
Control and Command rooms, hospitals, schools
Survival electrical and telecommunications installations,
Assembly locations, Garages, safety zones and emergency evacuation.
Areas with corrosive characteristics, extreme temperatures, and possible subjected to strong impacts.
Ideal for emergency lighting in tunnels and underground installations
Halogen-free, not containing Fluorine, Chlorine, Bromine or other halogenated compounds according to Standards EN50267-2 and EN 50267-2-3
The JSL BOXLINE FIRE range of boxes certified to E90 conditions according to the Standard
DIN 4102 Part.12
Boxes with easy-to-open premarked entries compatible with M20, M25, M32
![marke90top1 marke90top1](https://jsl-online.com/wp-content/uploads/2020/03/marke90top1.png)
![marke90top2 marke90top2](https://jsl-online.com/wp-content/uploads/2020/03/marke90top2.png)
![ve90 fire proof cable gland enclosures JSL marke90bucim2](https://jsl-online.com/wp-content/uploads/2020/03/marke90bucim2.png)
![e90 fire proof cable gland enclosures JSL marke90bucim3](https://jsl-online.com/wp-content/uploads/2020/03/marke90bucim3.png)
![marke90bucim1 marke90bucim1](https://jsl-online.com/wp-content/uploads/2020/03/marke90bucim1.png)
CHARACTERISTICS
dowels treated for fire
conditions (Certified at
Deutsches Institut für
Bautechnik).
(optionally, they can be supplied with M6x25 “Umbrako” screws in zinc plated steel for mounting on metal cable tray “platines”)
![E90boxscheme2](https://jsl-online.com/wp-content/uploads/2019/07/CaixaE90esquema2.png)
resistant to furnace high
temperature, VDE certified.
Boxes molded in V0
selfextinguishing material. –
Certified KEMA KEUR
according to IEC EN
60670-22. (Insulation Class II)
Housing in self-extinguishing material V0, environmentally safe and free of harmful substances
Fire resistance time: 90 minutes – E90 Classification;
Tested and Certified by ATIF-LICOF test facility
Supplied with Steatite Ceramic Bar
![e90 fire proof boxes enclosures JSL markej100](https://jsl-online.com/wp-content/uploads/2020/03/markej100.png)
![CeramicasVert2 CeramicasVert2](https://jsl-online.com/wp-content/uploads/2019/07/CeramicasVert2.png)
![BarrasCeramicasTamanhos BarrasCeramicasTamanhos](https://jsl-online.com/wp-content/uploads/2019/07/BarrasCeramicasTamanhos.png)
Bar connector with 6 mm2 to 50 mm2of clamping area
The boxes may be provided with connecting bars of other of other capacities (on request)
OBTAIN BETTER PROTECTION WITH THE METALLIC ARMOR IK10
![refJ100-SF-MPC refJ100 SF MPC](https://jsl-online.com/wp-content/uploads/2019/07/refJ100-SF-MPC.png)
![Refj100-sf-mcp2 Refj100 sf mcp2](https://jsl-online.com/wp-content/uploads/2019/07/Refj100-sf-mcp2.png)
J100MF
No. of bars included: 3 x 6 mm2
Max. No. of Ceramic bars per box: 3
(Cable glands not included)
![J100MF-en J100MF en](https://jsl-online.com/wp-content/uploads/2020/06/J100MF-en.png)
J100MF-P10
No. of bars included: 3 x 10 mm2
Max. No. of Ceramic bars per box: 3
(Cable glands not included)
![J100MF-P10-en J100MF P10 en](https://jsl-online.com/wp-content/uploads/2020/06/J100MF-P10-en.png)
J100MF-P16
No. of bars included: 2 x 16 mm2
Max. No. of Ceramic bars per box: 2
(Cable glands not included)
![J100MF-P16-en J100MF P16 en](https://jsl-online.com/wp-content/uploads/2020/06/J100MF-P16-en.png)
J160MF
No. of bars included: 3 x 10 mm2
Max. No. of Ceramic bars per box: 4
![J160MF-en J160MF en](https://jsl-online.com/wp-content/uploads/2020/06/J160MF-en.png)
J160MF-P16
No. of bars included: 3 x 16 mm2
Max. No. of Ceramic bars per box: 3
![J160MF-P16-en J160MF P16 en](https://jsl-online.com/wp-content/uploads/2020/06/J160MF-P16-en.png)
J200MF
No. of bars included: 3 x 16 mm2
Max. No. of Ceramic bars per box: 4
![J200MF-en J200MF en](https://jsl-online.com/wp-content/uploads/2020/06/J200MF-en.png)
J200MF-P33
No. of bars included: 3 x 33 mm2
Max. No. of Ceramic bars per box: 4
![J200MF-P33-en J200MF P33 en](https://jsl-online.com/wp-content/uploads/2020/06/J200MF-P33-en.png)
J200MF-P50
No. of bars included: Sob Consulta
Max. No. of Ceramic bars per box: On request
![J200MF-P50-en J200MF P50 en](https://jsl-online.com/wp-content/uploads/2020/06/J200MF-P50-en.png)
J100-SF MCP
Metallic armor protection IK10 for J100MF
![refJ100-SF-MPC refJ100 SF MPC](https://jsl-online.com/wp-content/uploads/2019/07/refJ100-SF-MPC.png)
M20/V0 | M25/V0
V0 Metric cable glands