INDUSTRIAL PLUGS AND SOCKETS

IP44 INDUSTRIAL PLUGS AND SOCKETS

Fichas tomadas industriais IP44
Information

JSL IP44 Industrial Plugs and Sockets for indoor and outdoor installations, not subject to direct water exposure, such as water jets

IP67 INDUSTRIAL PLUGS AND SOCKETS

Fichas tomadas industriais IP67
Information

JSL IP67 Industrial Plugs and Sockets indicated for installations of high degree of tightness, impact resistance and temperature.
Best solution for shopping centers, hospitals, offices and all types of industries

Industrial plugs and sockets JSLIn the industrial sector, construction, or agriculture, electrical demands far exceed those of a domestic installation. High-power equipment requires robust connections, capable of withstanding high currents and the most adverse environmental conditions, from humidity and splashes to immersion and full exposure to the elements. This is where industrial plugs and sockets come in.

At JSL Material Eléctrico, we offer high-performance connection solutions, designed to ensure operator safety and continuity of power supply, minimizing breakdowns and downtime on-site or on the production line.

The Right Protection for Your Project: IP44 or IP67?

Selecting the correct industrial plug or socket depends fundamentally on the installation environment and the degree of exposure to dust and liquids. JSL organizes its range according to the Ingress Protection (IP) rating, in compliance with standards EN 60309-1, EN 60309-2, EN 60529 and EN 62262:

  • Industrial plugs and sockets IP44IP44 Industrial Plugs and Sockets: The recommended solution for environments with moderate humidity and subject to splashes. The IP44 rating guarantees protection against the ingress of solid bodies larger than 1 mm and water splashes from any direction. Frequently used in warehouses, covered workshops, construction sites, and industrial halls, with the advantage of allowing quick and practical connection and disconnection.
  • Industrial plugs and sockets IP67IP67 Industrial Plugs and Sockets: Designed for the most demanding scenarios. With total dust-tightness and resistance to temporary water immersion, they are the recommended choice for outdoor work, ports, chemical industries, wash-down areas, and agricultural operations. The threaded ring locking system ensures that the connection does not accidentally come loose and keeps the contacts perfectly sealed.

Standardization, Mechanical Resistance, and Ease of Wiring

The entire JSL industrial switchgear range complies with the IEC 60309 standard, ensuring universal compatibility through the international color code: blue for 230 V single-phase networks and red for 400 V three-phase networks.

Beyond electrical safety, JSL plugs and sockets stand out for their high mechanical resistance to drops and impacts common on-site, and for their ease of wiring with wide terminals and efficient cable gland systems that simplify the electrician’s work and prevent dangerous strain on the internal conductors.

Refer to the informational diagram below to assertively select the amperage, number of poles, and protection rating configuration suited to your project. Explore the subcategories above to find the right solution for each installation.

tomada para montagem quadro tomada angulo tomada ip44 tomada ip67
IP44 IP67 IP44 IP67 IP44 IP67 IP44 IP67
A Volt. Pins Ref. Ref. Ref. Ref. Ref. Ref. Ref. Ref.
16 ≈ 230 2P+T(E) 9210/TC
≈ 230 2P+T(E) 9316/1
9316/1N
679316/1 9316/2N 679316/2 9316/3 679316/3 9316/4 679316/4
≈ 400 3P+T(E) 9416/1 679416/1 9416/2N 679416/2 9416/3 679416/3 9416/4 679416/4
≈ 230/400 3P+ N+T(E) 9516/1 679516/1 9516/2N 679516/2 9516/3 679516/3 9516/4 679516/4
32 ≈ 230 2P+T(E) 9332/1 679332/1 9332/2N 679332/2 9332/3 679332/3 9332/4 679332/4
≈ 400 3P+T(E) 9432/1 679432/1 9432/2N 679432/2 9432/3 679432/3 9432/4 679432/4
≈ 230/400 3P+ N+T(E) 9532/1 679532/1 9532/2N 679532/2 9532/3 679532/3 9532/4 679532/4
63 ≈ 250 2P+T(E) 679363/5 679363/6 679363/7 679363/8
≈ 415 3P+T(E) 679463/5 679463/6 679463/7 679463/8
≈ 240/415 3P+ N+T(E) 679563/5 679563/6 679563/7 679563/8

SEE THE FOLLOWING INFORMATION DIAGRAM

SO YOU CAN ASSERTIVELY CHOOSE ACCORDING TO THE NEED FOR INSTALLATION

According to Standards:

EN 60309-1
EN 60309-2
EN 60529 (for IP)
EN 62262 (for IK)

Esquema fichasTomadas